Open assessments
0projects
High risk / PLe hazards
0need action
Pending items
0open hazards
Total hazards assessed
0all projects
Closed / mitigated
0hazards
Quick start
Recent projects
Loading projects...
Standards active
ISO 13849-1:2023
IEC 62061:2021
ISO 13855:2010
ANSI B11.19:2019
ANSI B11.0:2020
ISO 12100:2010
R15.306-2016
ISO 10218-1/2
Approach direction
ISO 13855:2010 §5 — K = 2000 mm/s (orthogonal) · 1600 mm/s (parallel)
Device type & beam configuration
Determines D_DS reaching distance and installation rules
Affects reaching distance per ISO 13855 Annex C
Distance inputs
Total stop time from signal to hazard cessation
Light curtain response time from manufacturer datasheet
Auto-set by iteration: K=2000 if S≤500mm, K=1600 if S>500mm (ISO 13855 §5.2.2)
Light curtain: 8×(d−14mm) · Light beam ≥2: 850mm · Single beam: 1200mm · Whole-body: 1200mm
If checked → D_DS auto-set to 1200 mm per ISO 13855 §4.3 and ANSI B11.19 §10
Beam installation checks — ISO 13855 Annex C
Enter actual beam installation heights to verify compliance. These are checked but do not affect the distance calculation.
Max 300 mm (industrial) or 200 mm (risk-assessment justified)
Min 900 mm to prevent stepping over detection zone
Min 400 mm between beams for multi-beam devices
Single beam: opening must be ≤ 500 mm
Risk Graph Parameters — ISO 13849-1:2023 Annex A
Select parameters to determine required Performance Level ()
MTTFd / DC / PFHd Calculator — ISO 13849-1:2023 Annex K
Quantify channel reliability for performance level verification
Max 100 years per ISO 13849-1 §4.5.2
For Category 3/4 (dual channel)
Per ISO 13849-1 Annex F checklist
Select hazard type to get device recommendations
⚠ For reference only. Results must be reviewed and validated by a competent person per ISO 12100:2010. Vector Safety LLC assumes no liability for decisions made based on this tool.
Project information
Step 1 — Define tasks
No tasks yet. Add tasks first, then assess hazards within each task.
Common tasks (click to add):
Step 2 — Hazard assessment
Add tasks above, then click "+ Add hazard line" to begin assessing hazards within each task.
IEC 61800-5-2 Safety functions reference
▼ show
For reference only. All assessments must be reviewed by a qualified Functional Safety Engineer. Vector Safety LLC assumes no liability.
Loaded standards
API Key Setup
Your API key is stored only in this browser — never sent to Vector Safety servers or visible in the app code.
Get your key at console.anthropic.com → API Keys. Never share your key with anyone.
Machine Safety AI Advisor
Ask about ISO 13849, IEC 62061, ANSI B11, safe distances, risk assessment, or device selection.
Hello! I'm your Machine Safety Expert advisor for Vector Safety LLC. I'm trained on ISO 13849, IEC 62061, ISO 13855, and ANSI B11 standards. Ask me about performance levels, safe distance calculations, risk assessment methodology, safety device selection, or any other machine safety topic. How can I help you today?
Responses are for informational guidance only. All safety designs must be validated by a qualified FSE. No standard text is reproduced.
User accounts
Loading...
All projects